- manufacturer of precision test and measurement equipmentVoltage-Current CalibratorModel 828FEATURESAC/DC OutputWide Range - 1 Millivolt to 1100 Volts, 1 Microampere to 5 AmperesHigh AccuracyEase of OperationHigh StabilityDirect Reading Percent Deviation ofOutput ControlHigh Burden and Compliance RatingsShort Circuit and Overburden ProtectionContinuous Resolution Run-up for Analog Meter Friction TestingCompact Size for Ease of Portability and Minimum Bench SpaceRequirementsRapid Warm-upAPPLICATIONSCalibration of: Designed for use in:Analog Panel Meters Production Line TestingPortable Volt-Amp Multimeters Laboratory Calibration3 1/2 Digit Panel Meters Field Calibration ServiceTransducers Plant CalibrationRecordersDESCRIPTIONThe Model 828 AC/DC Source is a compact, self-regulating instrument capable of meeting a highpercentage of calibration requirements for laboratory, production line and field use. A minimum number ofcontrols assure ease of operation for all grades of personnel. Output voltage and current are set by fingertipoperation of a centrally located digital readout /selector control. Setting time is less than 1.5 second.Voltage output is covered in four ranges: 1V, 10V, 100V and 1000V with 100% over-range on the threeVoltage-Current Calibrator - Model 828http://www.clarke-hess.com/828.html (1 of 3) [9/20/2001 3:41:10 PM]
- lower ranges and 10% over-range on the 1000V range. Current is supplied in five full-scale ranges of 1, 10,100mA and 1 and 10A. Over-range is 100% on all ranges except the 10A range where maximum output is5A.High burden capability is achieved by a rating of 10VA on the higher voltage ranges and a rating of 5VAon the one volt range. Compliance of the current ranges is 5V except for the 10A range where it is 1V.The percent error of a meter under test may be quickly determined and directly read by use of the Model828's Percent Error control. Analog meters may be tested for 'sticky' movements by use of the run-upmode which allows voltage or current to be smoothly and continuously applied to the meter under test.The calibrator supplies voltage and current at dc and at internally generated frequencies of 50, 60 and 400Hz. Low ripple on dc functions and low distortion in ac modes minimizes random error when calibratingdigital and rectifier type instruments. It is protected against accidental short circuit or overburdening of theoutput by internal sense circuitry which removes the output voltage or current if the load ratings areexceeded.High output stability makes this instrument suitable for use as a constant current or constant voltage source.SPECIFICATIONSOUTPUT SPECIFICATIONSVoltage SourceFull Scale Ranges: Four: 1, 1 0, 1 00, and 1 000 V.Overrange Limits: 1100 volts on 1000 V range;200% of full-scale value on all other ranges.Stability: 0.05%/8 hours; within rated accuracy for 6 months.Voltage Burden: 5 VA on 1 V range; 10 VA on all other ranges.Current SourceFull Scale Ranges: Five: 1, 10, and 100 mA; 1 and 10AOverrange Limits: 5 amps on 10A range; 200% of full-scale value on all other ranges.Compliance: 1 volt on 10 A range; 5 volts on all other ranges.ACCURACYOutput Mode AccuracyDc Voltage (0.05% of setting + 0.05% of range)Ac Voltage (0.05% of setting + 0. 1 % of range)Current (0. 1 % of setting + 0. 1 % of range)GENERALTotal Harmonic Distortion Less than 0.3% at full-scale.Ripple (Dc Operation Only) Less than 1 % rms at full-scale with 1 M load.Internal Frequency SourceFrequencies: 50, 60, and 400 Hz.Accuracy: 50 and 400 Hz: l %60 Hz: 0.5%External Frequency InputVoltage-Current Calibrator - Model 828http://www.clarke-hess.com/828.html (2 of 3) [9/20/2001 3:41:10 PM]
- Frequency Limits: 50 to 440 Hz.Input Voltage 3 volts maximum% Deviation ControlRange: 2% of setting, adjustable via front panel control.Accuracy: l /2 division (0.05%).Warm-Up Time Less than 3 minutes at room temperature.Operating Temperature +18C to+28C (+65F to+82F) for rated accuracy; the Model 828may be operated from C to +1 8C (+32F to +65F) and +28Cand +50C (+82F to +122F) at derated specifications.Input Power RequirementsStandard: 115 V Operation: 104 to 127 volts, 47 to 63 Hz, 45 watts230 V Operation: 207 to 253 volts, 47 to 63 Hz, 45 wattsOptional: 100 V Operation: 90 to 110 volts, 47 to 63 Hz, 45 watts200 V Operation: 1 80 to 220 volts, 47 to 63 Hz, 45 wattsDimensionsHeight: 1 9 cm (71/2 inches)Width: 21.6 cm (81/2 inches)Depth: 33 cm (13 inches)Weight: 25 lbs (11.3 kg)clarke-hess21-09 43 Avenue, Long Island City, NY 11101-5016Phone: (718) 784-0445 Fax: (718) 784-2438Voltage-Current Calibrator - Model 828http://www.clarke-hess.com/828.html (3 of 3) [9/20/2001 3:41:10 PM]http://www.clarke-hess.com/index.htmmailto:[email protected]
Categories
- >Calibrators
- >Electrical Testers
- >Flow Equipment
- >Hi-Voltage & Insulation
- >MultiMeters & Clamp-On
- >Oscilloscopes & Spectrum Analyzers
- >Power Supplies & Function Generators
- >Pressure Equipment
- >Transformer Testers
- More categories
- > Calibration Resistors & Shunts
- >Cable, Pipe & Fault Locator
- >Communication Analyzers & Data Loggers
- >Gas Detectors
- >Meters
- >Temperature & Humidity
- >Vibration, Speed & Sound
Register | Login |
May 30, 2017 Clarke Hess 828 Manual Lymphatic Drainage. 5/30/2017 0 Comments Reflexology. Reflexology is a unique method of using the thumb and fingers to stimulate more than seven thousand nerve endings in each foot. These nerve endings correspond to all parts of the body, including organs and glands. Stimulating the appropriate region is intended to. Clarke Hess 828 Manual Lymphatic Drainage. 5/30/2017 0 Comments Reflexology. Reflexology is a unique method of using the thumb and fingers to stimulate more than seven thousand nerve endings in each foot. These nerve endings correspond to all parts of the body, including organs and glands. Stimulating the appropriate region is intended to.
Make: | CLARKE HESS |
Model: | 828 |
Dealer: | User Equip |
File | CLARKE HESS 828 Instruction Manual.pdf |
Share technical documentation including product manuals, getting started guides, and specifications.
We hope User Equip will be useful for all technicians, working in the field of electronic repairs. Here one can find information about many different types of equipment. If you have something that you might think might be usefull to others please share. In this community we like to help each other out. If you have anything old or new please share.
Contact usAbout usTerms & ConditionsCopyright ©2020.